Operation
An earth connection is not necessary for the safety or correct operation of the detectors. The ground terminal (earth) is insulated and is provided for the correct termination of grounded conductors or cable screens and to maintain ground continuity when necessary.
All terminals are marked according to their function.
The bases have a large internal diameter to facilitate access to the cables and terminals and there are two slots for fixing the screws. The slots allow two fixing screws to be placed at a spacing of 51 mm to 69 mm.
The detectors fit into the sockets in just one way, without clamping, and require clockwise rotation without pressure to be connected.
Device addressing
Universal address cards, known as XPERT cards, are supplied with all bases. Refer to the coding guide in the installation instructions to determine which pips must be removed from the card to provide the correct address. Place the card on a flat surface, pips down, insert a screwdriver into the slot on the back of the pip to be removed and give it a firm twist.
Once the card has been encoded, insert it into the slot on the side of the appropriate base, making sure that the card clicks into place. As a detector is inserted into the base, the remaining pips operate on the address buttons on the detector and the detector’s electronics read the address. An anti-tamper screw on the cover locks the detector into the mounting base. A 1.5 mm hex key, ref. 29600-095, is available.
Key features
- XPERT Addressing
- Unilateral detector adjustment
- Locking feature to prevent unauthorized removal of the detector