Orbis Base LX

Reference: ORB-MB-00012APO
Brand:
Category:
In stock

The Orbis LX Base has two openings for fixing screws at a spacing of 51mm and 69mm. The detectors fit into the base in only one way and require clockwise rotation without force to be connected.

Share

Brand Information
Orbis® is a range of conventional detectors that has been developed and tested to create advantages for fire engineers and installers, as well as building owners and users.

Orbis is a range with modern styling and a mounting base that saves installation time. It is electrically compatible with Apollo Series 65 and previous ranges of conventional detectors.

Orbis is a demonstration of Apollo’s commitment to the market for high-quality conventional detectors for use in small to medium-sized installations. In developing this range, Apollo has put ease of installation and reliability in day-to-day operation at the forefront of considerations. The attractive, compact design means that Orbis blends in well with all architectural styles.

Orbis is manufactured at the Apollo factory near Portsmouth, England.

Orbis has been tested and approved according to the following standards:

EN54-7: 2000 + A1: 2002
optical smoke detector

EN 54-7: 2000 + A1: 2002 and
CEA 4021: 2003-07

multisensor smoke detector
EN 54-5: 2000 + A1: 2002
heat detector

The detectors have been declared to comply with the essential requirements of the EMC Directive 2004/108 / EEC and the Construction Products Directive 89/106 / EEC.

Brand characteristics

  • TimeSaver Base® designed for quick installation
  • StartUp ™ for fast commissioning
  • FasTest® reduces maintenance time
  • automatic drift compensation
  • DirtAlert® warning to easily identify dirty detectors
  • SensAlert® which indicates that the detector is not working properly
  • wide operating voltage and temperature range
  • optical sensor designed for high reliability and reduced incidence of false alarms
  • multisensor smoke detector for detecting fast-burning fires
  • itermitent LED option

Maintenance service
Detectors should be checked regularly at the intervals indicated by the locally applicable code of practice. Apollo recommends that detectors be checked at least once a year.

One of Orbis’ features is FasTest®, which makes it possible to perform a functional test, using smoke or heat, in around four seconds. If the detectors appear not to be working properly, they should be returned to Apollo for testing.

If the detectors are dirty externally, they can be cleaned carefully with a damp cloth and a small amount of industrial alcohol.

DirtAlert ™
Orbis detectors have drift compensation to compensate for changes caused by the environment. The most common change is contamination.

If the detector is so dirty that it can no longer compensate, the LED will flash yellow while it is initializing.

Therefore, maintenance checks should include removing a detector from its base and reinserting it or pressing reset on the control panel to mimic initialization. A flashing yellow LED is not a sign that the detector needs to be replaced immediately. The decision to replace must be made by the service engineer, taking into account the detector’s environment. If the detector is not replaced, it will end up causing false alarms.

When deciding how long to leave the detector in place in such a case, the following rule of thumb can be used: installation time + 25%.
For example, if a detector has been installed for four years when the LED flashes yellow, it can remain in place for up to 12 months.

Dirty detectors can be returned to Apollo for cleaning and recalibration.

Additional Information
Orbis has been designed with a number of features that make commissioning easier and save time.

StartUp

When Orbis detectors are switched on, they automatically enter a phase known as StartUp, in which they remain for 4 minutes. After that, they return to normal operation. If the detector is restarted, i.e. if the power is disconnected for a second or more, the detector will always enter startup within the first four minutes after the power is restored. The detector’s LED flashes red once a second to indicate that it is initializing.

What StartUp says

StartUp is used to check that the positive and negative cables are connected in the correct polarity and that power has been applied to the detector. If this is the case, the LED will flash red once every second.

StartUp will not check whether the IN+ and OUT+ connections have been crossed. This is not a problem if the standard sockets are used, as the detector will work normally.

If, however, diode bases are used and a detector is removed from a base with transposed positive connections, none of the detectors beyond this point will operate.

FasTest®

Orbis detectors incorporate a test facility known as FasTest®.

In normal operation, Orbis smoke detectors do not switch to alarm status at the first smoke detection. If they did, they could be very sensitive and cause false alarms. Algorithms determine the point at which the detector switches to alarm.

This can slow down the maintenance routine during which detectors are tested using smoke or a simulating substance.

To avoid this problem, Orbis detectors have FasTest, a feature that is automatically available during StartUp and which modifies algorithms so that testing is possible in 4 seconds.

The test problem is even more acute in the case of heat detectors, as they absorb a large amount of heat during the test. Orbis heat detectors also incorporate FasTest®.

In the case of heat detectors, a rapid test is defined as a sample that recognizes an increase of 10°C in one minute. As sampling takes place every 2 seconds, an Orbis heat detector will respond in around 4 seconds.

Smoke or Heat Test

The testing of Orbis detectors is aided by the FasTest® feature. A detector will react quickly to the correct stimulus if applied within 4 minutes of being switched on.

Choose the appropriate test function on the control panel and restart the detector circuit. This should put the detectors into FasTest® mode. Apply smoke or heat as appropriate and the detector should go into alarm within 4 seconds. The control panel may sound the alarm and reset the zone automatically (see control panel instructions). Otherwise, silence the alarm and restart the panel. Repeat the procedure as necessary.

Note that the multisensor detector will respond to smoke or heat while in FasTest® mode.

Main Features

  • Unidirectional fitting
  • Detector fixing mechanism

Sem características de produto para apresentar.

ORBIS Information
ORBIS Installation Guide
ORBIS Product Guide

Manufacturer information

Manufacturing information includes the address and related information of the product manufacturer

No information to present at the moment.

Responsible EU person

EU-based economic operator who guarantees that the product complies with the required regulations.

No information to present at the moment.

Product safety images

Product safety images contain information about product packaging and can provide key safety information for a specific product.

No information to present at the moment.

Related Products

Orbis I.S. Timesaver Base

ORBIS – Product Range – Conventional System

Series 65 Base

APOLLO Products – Full Range

Find out more about this product. Contact us for more information.

Por favor preencha o formulário abaixo para solicitar mais informações.

Please fill in the form below to request more information.